The reference validation cabling is documented in the following tables.
The following table lists cabling information for Cisco Nexus switch 31108PCV A.
Local device | Local port | Remote device | Remote port |
---|---|---|---|
Cisco Nexus switch 31108PCV A |
Eth1/1 |
NetApp AFF A220 storage controller A |
e0M |
Eth1/2 |
Cisco UCS-mini FI-A |
mgmt0 |
|
Eth1/3 |
Cisco UCS-mini FI-A |
Eth1/1 |
|
Eth 1/4 |
Cisco UCS-mini FI-B |
Eth1/1 |
|
Eth 1/13 |
Cisco NX 31108PCV B |
Eth 1/13 |
|
Eth 1/14 |
Cisco NX 31108PCV B |
Eth 1/14 |
The following table lists the cabling information for Cisco Nexus switch 31108PCV B.
Local device | Local port | Remote device | Remote port |
---|---|---|---|
Cisco Nexus switch 31108PCV B |
Eth1/1 |
NetApp AFF A220 storage controller B |
e0M |
Eth1/2 |
Cisco UCS-mini FI-B |
mgmt0 |
|
Eth1/3 |
Cisco UCS-mini FI-A |
Eth1/2 |
|
Eth 1/4 |
Cisco UCS-mini FI-B |
Eth1/2 |
|
Eth 1/13 |
Cisco NX 31108PCV A |
Eth 1/13 |
|
Eth 1/14 |
Cisco NX 31108PCV A |
Eth 1/14 |
The following table lists cabling information for NetApp AFF A220 storage controller A.
Local device | Local port | Remote device | Remote port |
---|---|---|---|
NetApp AFF A220 storage controller A |
e0a |
NetApp AFF A220 storage controller B |
e0a |
e0b |
NetApp AFF A220 storage controller B |
e0b |
|
e0e |
Cisco UCS-mini FI-A |
Eth1/3 |
|
e0f |
Cisco UCS-mini FI-B |
Eth1/3 |
|
e0M |
Cisco NX 31108PCV A |
Eth1/1 |
The following table lists cabling information for NetApp AFF A220 storage controller B.
Local device | Local port | Remote device | Remote port |
---|---|---|---|
NetApp AFF A220 storage controller B |
e0a |
NetApp AFF A220 storage controller B |
e0a |
e0b |
NetApp AFF A220 storage controller B |
e0b |
|
e0e |
Cisco UCS-mini FI-A |
Eth1/4 |
|
e0f |
Cisco UCS-mini FI-B |
Eth1/4 |
|
e0M |
Cisco NX 31108PCV B |
Eth1/1 |
The following table lists cabling information for Cisco UCS Fabric Interconnect A.
Local device | Local port | Remote device | Remote port |
---|---|---|---|
Cisco UCS Fabric Interconnect A |
Eth1/1 |
Cisco NX 31108PCV A |
Eth1/3 |
Eth1/2 |
Cisco NX 31108PCV B |
Eth1/3 |
|
Eth1/3 |
NetApp AFF A220 storage controller A |
e0e |
|
Eth1/4 |
NetApp AFF A220 storage controller B |
e0e |
|
mgmt0 |
Cisco NX 31108PCV A |
Eth1/2 |
The following table lists cabling information for Cisco UCS Fabric Interconnect B.
Local device | Local port | Remote device | Remote port |
---|---|---|---|
Cisco UCS Fabric Interconnect B |
Eth1/1 |
Cisco NX 31108PCV A |
Eth1/4 |
Eth1/2 |
Cisco NX 31108PCV B |
Eth1/4 |
|
Eth1/3 |
NetApp AFF A220 storage controller A |
e0f |
|
Eth1/4 |
NetApp AFF A220 storage controller B |
e0f |
|
mgmt0 |
Cisco NX 31108PCV B |
Eth1/2 |