FlexPod Express cabling information
This reference validation is cabled as shown in the following figures and tables.
This figure shows the reference validation cabling.
The following table lists the cabling information for Cisco Nexus switch 31108PC-V-A.
Local device | Local port | Remote device | Remote port |
---|---|---|---|
Cisco Nexus switch 31108PC-V A |
Eth1/1 |
NetApp AFF C190 storage controller A |
e0c |
Eth1/2 |
NetApp AFF C190 storage controller B |
e0c |
|
Eth1/3 |
Cisco UCS C220 C-Series standalone server A |
MLOM0 |
|
Eth1/4 |
Cisco UCS C220 C-Series standalone server B |
MLOM0 |
|
Eth1/5 |
Cisco UCS C220 C-Series standalone server A |
MLOM1 |
|
Eth1/6 |
Cisco UCS C220 C-Series standalone server B |
MLOM1 |
|
Eth1/25 |
Cisco Nexus switch 31108PC-V B |
Eth1/25 |
|
Eth1/26 |
Cisco Nexus switch 31108PC-V B |
Eth1/26 |
|
Eth1/33 |
NetApp AFF C190 storage controller A |
e0M |
|
Eth1/34 |
Cisco UCS C220 C-Series standalone server A |
CIMC (FEX135/1/25) |
This table lists the cabling information for Cisco Nexus switch 31108PC-V- B.
Local device | Local port | Remote device | Remote port |
---|---|---|---|
Cisco Nexus switch 31108PC-V B |
Eth1/1 |
NetApp AFF C190 storage controller A |
e0d |
Eth1/2 |
NetApp AFF C190 storage controller B |
e0d |
|
Eth1/3 |
Cisco UCS C220 C-Series standalone server A |
MLOM2 |
|
Eth1/4 |
Cisco UCS C220 C-Series standalone server B |
MLOM2 |
|
Eth1/5 |
Cisco UCS C220 C-Series standalone server A |
MLOM3 |
|
Eth1/6 |
Cisco UCS C220 C-Series standalone server B |
MLOM3 |
|
Eth1/25 |
Cisco Nexus switch 31108 A |
Eth1/25 |
|
Eth1/26 |
Cisco Nexus switch 31108 A |
Eth1/26 |
|
Eth1/33 |
NetApp AFF C190 storage controller B |
e0M |
|
Eth1/34 |
Cisco UCS C220 C-Series standalone server B |
CIMC (FEX135/1/26) |
This table lists the cabling information for NetApp AFF C190 storage controller A.
Local device | Local Port | Remote device | Remote port |
---|---|---|---|
NetApp AFF C190 storage controller A |
e0a |
NetApp AFF C190 storage controller B |
e0a |
e0b |
NetApp AFF C190 storage controller B |
e0b |
|
e0c |
Cisco Nexus switch 31108PC-V A |
Eth1/1 |
|
e0d |
Cisco Nexus switch 31108PC-V B |
Eth1/1 |
|
e0M |
Cisco Nexus switch 31108PC-V A |
Eth1/33 |
This table lists the cabling information for NetApp AFF C190 storage controller B.
Local device | Local port | Remote device | Remote port |
---|---|---|---|
NetApp AFF C190 storage controller B |
e0a |
NetApp AFF C190 storage controller A |
e0a |
e0b |
NetApp AFF C190 storage controller A |
e0b |
|
e0c |
Cisco Nexus switch 31108PC-V A |
Eth1/2 |
|
e0d |
Cisco Nexus switch 31108PC-V B |
Eth1/2 |
|
e0M |
Cisco Nexus switch 31108PC-V B |
Eth1/33 |