Power and cabling requirements
A FlexPod design has minimum requirements for power and cabling.
Power requirements
Power requirements for FlexPod Datacenter differ based on the location where the FlexPod Datacenter configuration is installed.
For more data about the maximum power that is required and for other detailed power information, consult the technical specifications for each hardware component listed in the section Technical Specifications and References: Hardware Components.
For detailed Cisco UCS power data, see the Cisco UCS power calculator.
For NetApp storage controller power data, see the NetApp Hardware Universe. Under Platforms, select the storage platform that you want to use in the configuration (FAS/V-Series or AFF). Select the ONTAP version and storage controller, and then click the Show Results button.
Minimum cable requirements
The number and type of cables and adapters that are required vary per FlexPod Datacenter deployment. The cable type, transceiver type, and number are determined during the design process based on your requirements. The table below lists the minimum number of cables required.
Hardware | Model number | Cables required |
---|---|---|
Cisco UCS chassis |
Cisco UCS 5108 |
At least two twinaxial cables per Cisco UCS 2104XP, 2204XP, or 2208XP module |
Cisco UCS Fabric Interconnects |
Cisco UCS 6248UP |
|
Cisco UCS 6296UP |
||
Cisco UCS 6332-16UP |
||
Cisco UCS 6454 |
||
Cisco UCS 6332 |
|
|
Cisco UCS 6324 |
|
|
Cisco Nexus 5000 and 7000 Series Switches |
Cisco Nexus 5000 Series |
|
Cisco Nexus 7000 Series |
||
Cisco Nexus 9000 Series Switches |
Cisco Nexus 9000 Series |
At least two 10GbE cables per switch |
NetApp FAS controllers |
AFF A-Series |
|
FAS Series |
||
NetApp disk shelves |
DS212C |
Two SAS, SATA, or FC cables per disk shelf |
DS224C |
||
DS460C |
||
NS224 |
Two 100Gbps copper cables per disk shelf |