Base infrastructure configuration
Network connectivity
The following network connections must be in place before you configure the infrastructure:
-
Link aggregation that uses port channels and virtual port channels (vPCs) is used throughout, enabling the design for higher bandwidth and high availability:
-
vPC is used between the Cisco FI and Cisco Nexus switches.
-
Each server has virtual network interface cards (vNICs) with redundant connectivity to the Unified Fabric. NIC failover is used between FIs for redundancy.
-
Each server has virtual host bus adapters (vHBAs) with redundant connectivity to the Unified Fabric.
-
-
The Cisco UCS FI is configured in end- host mode as recommended, providing dynamic pinning of vNICs to uplink switches.
Storage connectivity
The following storage connections must be in place before you configure the infrastructure:
-
Storage port interface groups (ifgroups, vPC)
-
10Gb link to switch N9K-A
-
10Gb link to switch N9K-B
-
In- band management (active-passive bond):
-
1Gb link to management switch N9K-A
-
1Gb link to management switch N9K-B
-
-
32Gb FC end-to-end connectivity through Cisco MDS switches; single initiator zoning configured
-
FC SAN boot to fully achieve stateless computing; servers are booted from LUNs in the boot volume that is hosted on the AFF storage cluster
-
All MEDITECH workloads are hosted on FC LUNs, which are spread across the storage controller nodes
Host software
The following software must be installed:
-
ESXi installed on the Cisco UCS blades
-
VMware vCenter installed and configured (with all the hosts registered in vCenter)
-
VSC installed and registered in VMware vCenter
-
NetApp cluster configured