Ethernet Switch Health Monitoring log collection

Contributors

You can use the log collection feature to collect switch-related log files in ONTAP. The Ethernet switch health monitor (CSHM) is responsible for ensuring the operational health of Cluster and Storage network switches and collecting switch logs for debugging purposes. This procedure guides you through the process of setting up and starting the collection of detailed Support logs from the switch and starts an hourly collection of Periodic data that is collected by AutoSupport.

Before you begin
  • Verify that you have set up your environment using the Cisco 3232C cluster switch CLI.

  • Switch health monitoring must be enabled for the switch. Verify this by ensuring the Is Monitored: field is set to true in the output of the system switch ethernet show command.

Steps
  1. Create a password for the Ethernet switch health monitor log collection feature:

    system switch ethernet log setup-password

    Show example
    cluster1::*> system switch ethernet log setup-password
    Enter the switch name: <return>
    The switch name entered is not recognized.
    Choose from the following list:
    cs1
    cs2
    
    cluster1::*> system switch ethernet log setup-password
    
    Enter the switch name: cs1
    Would you like to specify a user other than admin for log collection? {y|n}: n
    
    Enter the password: <enter switch password>
    Enter the password again: <enter switch password>
    
    cluster1::*> system switch ethernet log setup-password
    
    Enter the switch name: cs2
    Would you like to specify a user other than admin for log collection? {y|n}: n
    
    Enter the password: <enter switch password>
    Enter the password again: <enter switch password>
  2. To start log collection, run the following command, replacing DEVICE with the switch used in the previous command. This starts both types of log collection: the detailed Support logs and an hourly collection of Periodic data.

    system switch ethernet log modify -device <switch-name> -log-request true

    Show example
    cluster1::*> system switch ethernet log modify -device cs1 -log-request true
    
    Do you want to modify the cluster switch log collection configuration? {y|n}: [n] y
    
    Enabling cluster switch log collection.
    
    cluster1::*> system switch ethernet log modify -device cs2 -log-request true
    
    Do you want to modify the cluster switch log collection configuration? {y|n}: [n] y
    
    Enabling cluster switch log collection.

    Wait for 10 minutes and then check that the log collection completes:

    system switch ethernet log show

    Caution If any of these commands return an error or if the log collection does not complete, contact NetApp support.
Troubleshooting

If you encounter any of the following error statuses reported by the log collection feature (visible in the output of system switch ethernet log show), try the corresponding debug steps:

Log collection error status

Resolution

RSA keys not present

Regenerate ONTAP SSH keys. Contact NetApp support.

switch password error

Verify credentials, test SSH connectivity, and regenerate ONTAP SSH keys. Review the switch documentation or contact NetApp support for instructions.

ECDSA keys not present for FIPS

If FIPS mode is enabled, ECDSA keys need to be generated on the switch before retrying.

pre-existing log found

Remove the previous log collection file on the switch.

switch dump log error