Skip to main content
ONTAP 7-Mode Transition

Testing transitioned SAN boot LUNs on HP-UX hosts before the cutover phase of copy-based transitions

Contributors

If you are using the 7-Mode Transition Tool (7MTT) 2.2 or later and Data ONTAP 8.3.2 or later to transition your HP-UX host SAN boot LUNs, you can test your transitioned clustered Data ONTAP LUNs before the cutover phase. Your source host can continue to run I/O to your source 7-Mode LUNs during testing.

Your new clustered Data ONTAP LUNs must be mapped to your test host and your LUNs must be ready for transition

You should maintain hardware parity between the test host and the source host, and you should perform the following steps on the test host.

Your clustered Data ONTAP LUNs are in read/write mode during testing. They convert to read-only mode when testing is complete and you are preparing for the cutover phase.

Steps
  1. After the baseline data copy is complete, select Test Mode in the 7MTT user interface (UI).

  2. In the 7MTT UI, click Apply Configuration.

  3. On the test host, enter the HBA BIOS.

  4. Change the IP address and host name on the test host.

  5. Verify that your clustered Data ONTAP LUNs are present on the test host:

    sanlun lun show

  6. Perform your testing as needed.

  7. Shut down the test host:

    shutdown -h -y 0

  8. In the 7MTT UI, click Finish Testing.

If your clustered Data ONTAP LUNs are to be remapped to your source host, you must prepare your source host for the cutover phase. If your clustered Data ONTAP LUNs are to remain mapped to your test host, no further steps are required on the test host.