Skip to main content
ONTAP 7-Mode Transition

Rolling back a copy-free transition project

Contributors

You can roll back a transition if you want to revert to 7-Mode at any stage of the copy-free transition before the transitioned aggregates are committed. Rollback is a manual operation. You can use the 7-Mode Transition Tool to generate the manual steps that you have to perform for a rollback.

  • You must ensure that no volume or aggregate transition operations are running on the cluster.

    You can use the job show -jobtype transition command.

  • None of the 7-Mode aggregates must be committed.

    Note You cannot perform the rollback if even one 7-Mode aggregate is committed.
  • The target cluster nodes must not be in takeover mode.

Steps
  1. Click Rollback Prechecks to verify that the project is eligible for a rollback.

    If the precheck reports issues, you must fix them manually and rerun the precheck operation. For example, if you have created any new volumes or LUNs during preproduction testing, you must delete them manually.

  2. Click Generate Rollback Steps to generate the list of manual steps that you have to perform for a successful rollback.

  3. Click Save As CSV to save the manual steps in a file.

    You can copy the rollback commands from the file and run them.

  4. Depending on the transition phase from which you decide to roll back, perform the required manual steps:

    • Import or preproduction testing phase

      1. Run the rollback commands on the cluster and click Confirm.

      2. Connect the 7-Mode disk shelves to the 7-Mode controllers, verify the cabling manually, and click Confirm.

      3. Run the rollback commands on the 7-Mode controllers and click Confirm.

      4. View the configurations that are applied on the SVMs from the Operations History tab.

      5. Manually remove all configurations that were applied by the tool from the SVMs.

    • Cabling phase

      1. Connect the 7-Mode disk shelves to the 7-Mode controllers, verify the cabling manually, and click Confirm.

        You must ensure that the 7-Mode cabling matches the way it was at the start of the project.

        Note You should use Config Advisor to verify the cabling.
      2. Run the rollback commands on the 7-Mode controllers and click Confirm.

      3. Manually remove all configurations that were applied by the tool from the SVMs.

        You can view the configurations that are applied on the SVMs from the Operations History tab.

    • Export phase

      1. Run the rollback commands on the 7-Mode controllers and click Confirm.

      2. Manually remove all configurations that were applied by the tool from the SVMs.

        You can view the configurations that are applied on the SVMs from the Operations History tab.

    • SVM provision phase

      Manually remove all configurations that were applied by the tool from the SVMs.

      You can view the configurations that are applied on the SVMs from the Operations History tab.

  5. After completing all the manual steps, click Verify 7-Mode from the 7-Mode Transition Tool to verify that the 7-Mode controllers are ready to serve data.