Skip to main content
OnCommand Unified Manager 9.5
A newer release of this product is available.

Performance/Volume or Performance/FlexGroup Information page

Contributors

Use this page to view a list of the physical and logical attributes of the volume. This information might help in answering performance-related questions. The title of this page depends on whether you are viewing a FlexVol volume or a FlexGroup volume.

Volume attributes

  • Type

    The volume's type; either read-write (RW) or data-protection (DP).

  • Style

    The style of volume; either FlexVol or FlexGroup.

    Note

    The performance pages of Unified Manager do not support Infinite Volumes.

  • Cluster

    The name of the cluster to which this FlexVol volume or FlexGroup volume belongs. You can click the name to display cluster details in the Performance/Cluster Explorer page.

  • Aggregates

    The name of the aggregate on which this FlexVol volume resides, or the number of aggregates on which this FlexGroup volume resides.

    For FlexVol volumes, you can click the name to display aggregate details in the Performance/Aggregate Explorer page. For FlexGroup volumes, you can click the number to display the aggregates that are used in this FlexGroup volume in the Performance/Aggregate Inventory page.

  • Storage Virtual Machine

    The name of the SVM to which this FlexVol volume or FlexGroup volume belongs. You can click the name to display SVM details in the Performance/SVM Explorer page.

  • Tiering Policy

    The tiering policy set on the volume. The policy takes affect only when the volume is deployed on a FabricPool aggregate. The available policies are:

    • None. The data for this volume always remains on the performance tier.

    • Snapshot Only. Only Snapshot data is moved automatically to the cloud tier. All other data remains on the performance tier.

    • Backup. On data protection volumes, all transferred user data starts in the cloud tier, but later client reads can cause hot data to move to the performance tier.

    • Auto. Data on this volume is moved between the performance tier and the cloud tier automatically when ONTAP determines that the data is “hot” or “cold”.

  • RAID Type

    The redundancy type that is being used on the performance tier of the aggregate where this volume resides. Possible types:

    • RAID0

    • RAID4

    • RAID-DP

    • RAID-TEC

    Note

    The value “Not Applicable” is displayed for FlexGroup volumes because the constituent volumes can be on aggregates of different RAID types.

  • Capacity (free/total)

    The total storage available on the volume, in gigabytes, and the amount of storage currently available.