Install or upgrade the RCF script
Follow this procedure to install or upgrade the RCF script.
Before installing or upgrading the RCF script, make sure that the following are available on the switch:
-
Cumulus Linux 4.4.3 is installed.
-
IP address, subnet mask, and default gateway defined via DHCP or manually configured.
There are two RCF scripts available for Clustering and Storage applications. The procedure for each is the same.
-
Clustering: MSN2100-RCF-v1.x-Cluster
-
Storage: MSN2100-RCF-v1.x-Storage
|
The following example procedure shows how to download and apply the RCF script for Cluster switches. |
|
Example command output uses switch management IP address 10.233.204.71, netmask 255.255.254.0 and default gateway 10.233.204.1. |
-
Display the available interfaces on the SN2100 switch:
net show interface all
Show example
cumulus@cumulus:mgmt:~$ net show interface all State Name Spd MTU Mode LLDP Summary ----- ----- --- ----- ----------- ------------------ -------------- ... ... ADMDN swp1 N/A 9216 NotConfigured ADMDN swp2 N/A 9216 NotConfigured ADMDN swp3 N/A 9216 NotConfigured ADMDN swp4 N/A 9216 NotConfigured ADMDN swp5 N/A 9216 NotConfigured ADMDN swp6 N/A 9216 NotConfigured ADMDN swp7 N/A 9216 NotConfigure ADMDN swp8 N/A 9216 NotConfigured ADMDN swp9 N/A 9216 NotConfigured ADMDN swp10 N/A 9216 NotConfigured ADMDN swp11 N/A 9216 NotConfigured ADMDN swp12 N/A 9216 NotConfigured ADMDN swp13 N/A 9216 NotConfigured ADMDN swp14 N/A 9216 NotConfigured ADMDN swp15 N/A 9216 NotConfigured ADMDN swp16 N/A 9216 NotConfigured
-
Copy the RCF python script to the switch:
admin@sw1:mgmt:~$ pwd /home/cumulus cumulus@cumulus:mgmt:~$ cd /tmp cumulus@cumulus:mgmt:/tmp$ scp <user>@<host:/<path>/MSN2100-RCF-v1.8-Cluster ssologin@10.233.204.71's password: MSN2100-RCF-v1.8-Cluster 100% 8607 111.2KB/s 00:00
-
Apply the RCF python script MSN2100-RCF-v1.8-Cluster:
cumulus@cumulus:mgmt:/tmp$ sudo python3 MSN2100-RCF-v1.8-Cluster [sudo] password for cumulus: ... Step 1: Creating the banner file Step 2: Registering banner message Step 3: Updating the MOTD file Step 4: Ensuring passwordless use of cl-support command by admin Step 5: Disabling apt-get Step 6: Creating the interfaces Step 7: Adding the interface config Step 8: Disabling cdp Step 9: Adding the lldp config Step 10: Adding the RoCE base config Step 11: Modifying RoCE Config Step 12: Configure SNMP Step 13: Reboot the switch
The RCF script completes the steps listed above.
For any RCF python script issues that cannot be corrected, contact NetApp Support for assistance. -
Reapply any previous customizations to the switch configuration. Refer to Review cabling and configuration considerations for details of any further changes required.
-
Verify the configuration after the reboot:
net show interface all
Show example
cumulus@cumulus:mgmt:~$ net show interface all State Name Spd MTU Mode LLDP Summary ----- --------- ---- ----- ---------- ----------------- -------- ... ... DN swp1s0 N/A 9216 Trunk/L2 Master: bridge(UP) DN swp1s1 N/A 9216 Trunk/L2 Master: bridge(UP) DN swp1s2 N/A 9216 Trunk/L2 Master: bridge(UP) DN swp1s3 N/A 9216 Trunk/L2 Master: bridge(UP) DN swp2s0 N/A 9216 Trunk/L2 Master: bridge(UP) DN swp2s1 N/A 9216 Trunk/L2 Master: bridge(UP) DN swp2s2 N/A 9216 Trunk/L2 Master: bridge(UP) DN swp2s3 N/A 9216 Trunk/L2 Master: bridge(UP) UP swp3 100G 9216 Trunk/L2 Master: bridge(UP) UP swp4 100G 9216 Trunk/L2 Master: bridge(UP) DN swp5 N/A 9216 Trunk/L2 Master: bridge(UP) DN swp6 N/A 9216 Trunk/L2 Master: bridge(UP) DN swp7 N/A 9216 Trunk/L2 Master: bridge(UP) DN swp8 N/A 9216 Trunk/L2 Master: bridge(UP) DN swp9 N/A 9216 Trunk/L2 Master: bridge(UP) DN swp10 N/A 9216 Trunk/L2 Master: bridge(UP) DN swp11 N/A 9216 Trunk/L2 Master: bridge(UP) DN swp12 N/A 9216 Trunk/L2 Master: bridge(UP) DN swp13 N/A 9216 Trunk/L2 Master: bridge(UP) DN swp14 N/A 9216 Trunk/L2 Master: bridge(UP) UP swp15 N/A 9216 BondMember Master: bond_15_16(UP) UP swp16 N/A 9216 BondMember Master: bond_15_16(UP) ... ... cumulus@cumulus:mgmt:~$ net show roce config RoCE mode.......... lossless Congestion Control: Enabled SPs.... 0 2 5 Mode........... ECN Min Threshold.. 150 KB Max Threshold.. 1500 KB PFC: Status......... enabled Enabled SPs.... 2 5 Interfaces......... swp10-16,swp1s0-3,swp2s0-3,swp3-9 DSCP 802.1p switch-priority ----------------------- ------ --------------- 0 1 2 3 4 5 6 7 0 0 8 9 10 11 12 13 14 15 1 1 16 17 18 19 20 21 22 23 2 2 24 25 26 27 28 29 30 31 3 3 32 33 34 35 36 37 38 39 4 4 40 41 42 43 44 45 46 47 5 5 48 49 50 51 52 53 54 55 6 6 56 57 58 59 60 61 62 63 7 7 switch-priority TC ETS --------------- -- -------- 0 1 3 4 6 7 0 DWRR 28% 2 2 DWRR 28% 5 5 DWRR 43%
-
Verify information for the transceiver in the interface:
net show interface pluggables
Show example
cumulus@cumulus:mgmt:~$ net show interface pluggables Interface Identifier Vendor Name Vendor PN Vendor SN Vendor Rev --------- ------------- ----------- --------------- -------------- ---------- swp3 0x11 (QSFP28) Amphenol 112-00574 APF20379253516 B0 swp4 0x11 (QSFP28) AVAGO 332-00440 AF1815GU05Z A0 swp15 0x11 (QSFP28) Amphenol 112-00573 APF21109348001 B0 swp16 0x11 (QSFP28) Amphenol 112-00573 APF21109347895 B0
-
Verify that the nodes each have a connection to each switch:
net show lldp
Show example
cumulus@cumulus:mgmt:~$ net show lldp LocalPort Speed Mode RemoteHost RemotePort --------- ----- ---------- ---------------------- ----------- swp3 100G Trunk/L2 sw1 e3a swp4 100G Trunk/L2 sw2 e3b swp15 100G BondMember sw13 swp15 swp16 100G BondMember sw14 swp16
-
Verify the health of cluster ports on the cluster.
-
Verify that e0d ports are up and healthy across all nodes in the cluster:
network port show -role cluster
Show example
cluster1::*> network port show -role cluster Node: node1 Ignore Speed(Mbps) Health Health Port IPspace Broadcast Domain Link MTU Admin/Oper Status Status --------- ------------ ---------------- ---- ---- ----------- -------- ------ e3a Cluster Cluster up 9000 auto/10000 healthy false e3b Cluster Cluster up 9000 auto/10000 healthy false Node: node2 Ignore Speed(Mbps) Health Health Port IPspace Broadcast Domain Link MTU Admin/Oper Status Status --------- ------------ ---------------- ---- ---- ----------- -------- ------ e3a Cluster Cluster up 9000 auto/10000 healthy false e3b Cluster Cluster up 9000 auto/10000 healthy false
-
Verify the switch health from the cluster (this might not show switch sw2, since LIFs are not homed on e0d).
Show example
cluster1::*> network device-discovery show -protocol lldp Node/ Local Discovered Protocol Port Device (LLDP: ChassisID) Interface Platform ----------- ------ ------------------------- --------- ---------- node1/lldp e3a sw1 (b8:ce:f6:19:1a:7e) swp3 - e3b sw2 (b8:ce:f6:19:1b:96) swp3 - node2/lldp e3a sw1 (b8:ce:f6:19:1a:7e) swp4 - e3b sw2 (b8:ce:f6:19:1b:96) swp4 - cluster1::*> system switch ethernet show -is-monitoring-enabled-operational true Switch Type Address Model --------------------------- ------------------ ---------------- ----- sw1 cluster-network 10.233.205.90 MSN2100-CB2RC Serial Number: MNXXXXXXGD Is Monitored: true Reason: None Software Version: Cumulus Linux version 4.4.3 running on Mellanox Technologies Ltd. MSN2100 Version Source: LLDP sw2 cluster-network 10.233.205.91 MSN2100-CB2RC Serial Number: MNCXXXXXXGS Is Monitored: true Reason: None Software Version: Cumulus Linux version 4.4.3 running on Mellanox Technologies Ltd. MSN2100 Version Source: LLDP
-