HP CommandView AE data source
The HP CommandView Advanced Edition (AE) and CommandView AE CLI/SMI (AE Lite) data sources support inventory and performance from a CommandView (also referred to as HiCommand) Device Manager server.
Terminology
OnCommand Insight acquires the following inventory information from the HP CommandView AE and AE Lite data sources. For each asset type acquired by Insight, the most common terminology used for this asset is shown. When viewing or troubleshooting this data source, keep the following terminology in mind:
Vendor/Model Term |
Insight Term |
PDEV |
Disk |
Journal Pool |
Disk Group |
Storage Array |
Storage |
Port Controller |
Storage Node |
Array Group, DP Pool |
Storage Pool |
Logical Unit, LDEV |
Volume |
These are common terminology mappings only and might not represent every case for this data source. |
Inventory Requirements
-
IP address of the HiCommand Device Manager server
-
Read-only user name and password for the CommandView AE software and peer privileges
-
The CommandView AE Lite version of the device manager has only the CLI licensed
-
Port requirement: 2001
Performance Requirements
-
HDS USP, USP V, and VSP performance
-
Performance Monitor must be licensed.
-
Monitoring switch must be enabled.
-
The Export Tool (
Export.exe
) must be copied to the OnCommand Insight Server. -
The Export Tool version must match the microcode version of the target array.
-
-
HDS AMS performance
-
Performance Monitor needs to be licensed.
-
The Storage Navigator Modular 2 (SNM2) CLI utility needs to be installed on the OnCommand Insight Server.
-
You must register all AMS, WMS, SMS storage arrays whose performance needs to be acquired by OnCommand Insight by using the following command:
auunitaddauto.exe -ip
<IP address of Controller0>
IP address of Controller1> -
You must ensure that all the arrays that you registered are listed in the output of this command:
auunitref.exe
.
-
Configuration
Field |
Description |
HiCommand Server |
IP address or fully-qualified domain name of the HiCommand Device Manager server |
User Name |
User name for the HiCommand Device Manager server. |
Password |
Password used for the HiCommand Device Manager server. |
Devices - USP, USP V, VSP/R600 Storages |
Device list for VSP G1000 (R800), VSP (R700), HUS VM (HM700) and USP storages. Each storage requires:
|
SNM2Devices - WMS/SMS/AMS Storages |
Device list for WMS/SMS/AMS storages. Each storage requires:
|
Choose Tuning Manager for Performance |
Choose Tuning Manager for performance and override other performance options |
Tuning Manager Host |
IP address or fully-qualified domain name of tuning manager |
Tuning Manager Port |
Port used for Tuning Manager |
Tuning Manager Username |
User name for Tuning Manager |
Tuning Manager Password |
password for Tuning Manager |
In HDS USP, USP V, and VSP, any disk can belong to more than one array group. |
Advanced configuration
Field |
Description |
HiCommand Server Port |
Port used for the HiCommand Device Manager |
HTTPs Enabled |
Select to enable HTTPs |
Inventory Poll Interval (min) |
Interval between inventory polls (default 40 minutes) |
Choose 'Exclude' or 'Include' to specify a list |
Specify whether to include or exclude the array list below when collecting data |
Exclude or Include Devices |
Comma-separated list of device ID's or array names to include or exclude |
Query Host Manager |
Select to query host manager |
HTTP Timeout (sec) |
HTTP connection timeout (default 60 seconds) |
Performance Polling Interval (sec) |
Interval between performance polls (default 300 seconds) |
Export timeout in seconds |
Export utility timeout (default 300 seconds) |