Skip to main content
ONTAP MetroCluster

Example of cabling storage array ports to FC switches in a four-node MetroCluster configuration

Contributors netapp-thomi netapp-aherbin

In a MetroCluster configuration with array LUNs, you must connect the storage array ports that form a redundant port pair to alternate FC switches.

The following reference illustration shows the connections between storage arrays and FC switches in a four-node MetroCluster configuration with array LUNs:

This graphic depicts an example MetroCluster configuration with array LUNs. The graphic is described by the surrounding text.
Note

If you plan to use disks in addition to array LUNs in your MetroCluster configuration, you must use the switch ports specified for the configuration with disks.

In the illustration, the redundant array port pairs for both the sites are as follows:

  • Storage array at Site A:

    • Ports 1A and 2A

    • Ports 1B and 2B

    • Ports 1C and 2C

    • Ports 1D and 2D

  • Storage array at Site B:

    • Ports 1A' and 2A'

    • Ports 1B' and 2B'

    • Ports 1C' and 2C'

    • Ports 1D' and 2D'

FC_switch_A_1 at Site A and FC_switch_B_1 at Site B are connected to form fabric_1. Similarly, FC_switch_A_2 at Site A and FC_switch_B_2 are connected to form fabric_2.

The following table lists the connections between the storage array ports and the FC switches for the MetroCluster illustration:

Array LUN ports

FC switch ports

Switch fabrics

Site A

1A

FC_switch_A_1, Port 7

fabric_1

2A

FC_switch_A_2, Port 11

fabric_2

1B

FC_switch_A_1, Port 8

fabric_1

2B

FC_switch_A_2, Port 10

fabric_2

1C

FC_switch_A_1, Port 9

fabric_1

2C

FC_switch_A_2, Port 9

fabric_2

1D

FC_switch_A_1, Port 10

fabric_1

2D

FC_switch_A_2, Port 8

fabric_2

Site B

1A'

FC_switch_B_1, Port 7

fabric_1

2A'

FC_switch_B_2, Port 11

fabric_2

1B'

FC_switch_B_1, Port 8

fabric_1

2B'

FC_switch_B_2, Port 10

fabric_2

1C'

FC_switch_B_1, Port 9

fabric_1

2C'

FC_switch_B_2, Port 9

fabric_2

1D'

FC_switch_B_1, Port 10

fabric_1

2D'

FC_switch_B_2, Port 8

fabric_2