In a MetroCluster configuration with array LUNs, you must connect the storage array ports that form a redundant port pair to alternate FC switches.
An eight-node MetroCluster configuration consists of two four-node DR groups. The first DR group consists of the following nodes:
-
controller_A_1
-
controller_A_2
-
controller_B_1
-
controller_B_2
The second DR group consists of the following nodes:
-
controller_A_3
-
controller_A_4
-
controller_B_3
-
controller_B_4
To cable the array ports for the first DR group, you can use the cabling examples for a four-node MetroCluster configuration for the first DR group.
To cable the array ports for the second DR group, follow the same examples and extrapolate for the FC-VI ports and FC initiator ports belonging to the controllers in the second DR group.