Requirements for nondisruptive FC-to-IP transition
Before starting the transition process, verify that the configuration meets the requirements.
You can perform a nodisruptive FC-to-IP transition if your configuration meets the following requirements:
- 
If you have an eight-node configuration, all nodes are running ONTAP 9.13.1 or later. 
- 
If you have a four-node configuration, all nodes are running ONTAP 9.8 or later. 
- 
The existing and new platforms are a supported combination for transition. 
- 
Your configuration supports a switched cluster configuration. 
|  | If you are using shared storage MetroCluster switches, you can only transition to a four-node MetroCluster IP configuration. Transitioning to an eight-node MetroCluster IP configuration using shared storage MetroCluster switches is not supported. After you complete the transition to a four-node MetroCluster IP configuration, you can expand to an eight-node MetroCluster IP configuration. | 
- 
Your configuration meets all requirements and is cabled as described in the following MetroCluster Installation and Configuration procedures. 