SG6060 and SG6060X appliances
The StorageGRID SG6060 and SG6060X appliances each include a compute controller and a storage controller shelf that contains two storage controllers and 60 drives. Optionally, 60-drive expansion shelves can be added to both appliances. There are no specification or functional differences between the SG6060 and SG6060X except for the location of the interconnect ports on the storage controller.
SG6060 and SG6060X components
The SG6060 and SG660X appliances includes the following components:
Component | Description |
---|---|
Compute controller |
SG6000-CN controller, a one-rack unit (1U) server that includes:
|
Storage controller shelf |
E-Series E2860 controller shelf (storage array), a 4U shelf that includes:
|
Optional: Storage expansion shelves Note: Expansion shelves can be installed during initial deployment or added later. |
E-Series DE460C enclosure, a 4U shelf that includes:
Each SG6060 and SG6060X appliance can have one or two expansion shelves for a total of 180 drives. |
SG6060 and 6060X diagrams
The fronts of the SG6060 and SG6060X are identical. The following figure shows the front of the SG6060, which includes a 1U compute controller and a 4U shelf containing two storage controllers and 60 drives in five drive drawers.
SG6060 front view
Callout | Description |
---|---|
1 |
SG6000-CN compute controller with front bezel |
2 |
E2860 controller shelf with front bezel (optional expansion shelf appears identical) |
3 |
SG6000-CN compute controller with front bezel removed |
4 |
E2860 controller shelf with front bezel removed (optional expansion shelf appears identical) |
The following figures show the rear of the SG6060 and SG6060X, including the compute and storage controllers, fans, and power supplies.
SG6060 rear view
Callout | Description |
---|---|
1 |
Power supply (1 of 2) for SG6000-CN compute controller |
2 |
Connectors for SG6000-CN compute controller |
3 |
Fan (1 of 2) for E2860 controller shelf |
4 |
E-Series E2800A storage controller (1 of 2) and connectors |
5 |
Power supply (1 of 2) for E2860 controller shelf |
SG6060X rear view
Callout | Description |
---|---|
1 |
Power supply (1 of 2) for SG6000-CN compute controller |
2 |
Connectors for SG6000-CN compute controller |
3 |
Fan (1 of 2) for E2860 controller shelf |
4 |
E-Series E2800B storage controller (1 of 2) and connectors |
5 |
Power supply (1 of 2) for E2860 controller shelf |
SG6060 and SG6060X expansion shelf
This figure shows the back of the optional expansion shelf for the SG6060 and SG6060X, including the input/output modules (IOMs), fans, and power supplies. Each SG6060 and SG6060X can be installed with one or two expansion shelves, which can be included in the initial installation or added later.
Callout | Description |
---|---|
1 |
Fan (1 of 2) for expansion shelf |
2 |
IOM (1 of 2) for expansion shelf |
3 |
Power supply (1 of 2) for expansion shelf |