When you apply power to the appliance, the BMC logs a series of boot-up codes. You can view these codes on a graphical console that is connected to the BMC management port.

What you'll need
  • You know how to access the BMC dashboard.

  • If you want to use serial-over-LAN (SOL), you have experience using IPMI SOL console applications.

Steps
  1. Select one of the following methods for viewing the boot-up codes for the appliance controller, and gather the required equipment.

    Method Required equipment

    VGA console

    • VGA-capable monitor

    • VGA cable

    KVM

    • RJ-45 cable

    Serial port

    • DB-9 serial cable

    • Virtual serial terminal

    SOL

    • Virtual serial terminal

  2. If you are using a VGA console, perform these steps:

    1. Connect a VGA-capable monitor to the VGA port on the back of the appliance.

    2. View the codes displayed on the monitor.

  3. If you are using BMC KVM, perform these steps:

    1. Connect to the BMC management port and log into the BMC web interface.

    2. Select Remote Control.

    3. Launch the KVM.

    4. View the codes on the virtual monitor.

  4. If you are using a serial port and terminal, perform these steps:

    1. Connect to the DB-9 serial port on the back of the appliance.

    2. Use settings 115200 8-N-1.

    3. View the codes printed over the serial terminal.

  5. If you are using SOL, perform these steps:

    1. Connect to the IPMI SOL using the BMC IP address and login credentials.

      Note If you haven't changed the BMC root account password, the factory-default value might be "calvin".

    ipmitool -I lanplus -H BMC_Port_IP -U root -P Password sol activate

    1. View the codes on the virtual serial terminal.

  6. Use the table to look up the codes for your appliance.

    Code Indicates

    HI

    The master boot script has started.

    HP

    The system is checking to see if the network interface card (NIC) firmware needs to be updated.

    RB

    The system is rebooting after applying firmware updates.

    FP

    The hardware subsystem firmware update checks have been completed. Inter-controller communication services are starting.

    HC

    The system is checking for existing StorageGRID installation data.

    HO

    The StorageGRID appliance is running.

    HA

    StorageGRID is running.

Related information