This message is generated when the DDS service cannot locate any copies of an object within the StorageGRID system.
Code | Field | Description |
---|---|---|
CBID |
Content Block Identifier |
The CBID of the lost object. |
NOID |
Node ID |
If available, the last known direct or nearline location of the lost object. It is possible to have just the Node ID without a Volume ID if the volume information is not available. |
PATH |
S3 Bucket/Key or Swift Container/Object ID |
If available, the S3 bucket name and S3 key name, or the Swift container name and Swift object identifier. |
RSLT |
Result |
This field has the value NONE. RSLT is a mandatory message field, but is not relevant for this message. NONE is used rather than SUCS so that this message is not filtered. |
UUID |
Universally Unique ID |
The identifier of the lost object within the StorageGRID system. |
VOLI |
Volume ID |