Remove the SGF6112 from a cabinet or rack to access the top cover or to move the appliance to a different location.

Before you begin
  • You have labels to identify each cable that is connected to the SGF6112.

  • You have physically located the SGF6112 where you are performing maintenance in the data center.

  • You have shut down the SGF6112.

    Caution Don't shut down the appliance using the power switch.
Steps
  1. Label and then disconnect the appliance power cables.

  2. Wrap the strap end of the ESD wristband around your wrist, and secure the clip end to a metal ground to prevent static discharge.

  3. Label and then disconnect the appliance data cables and any SFP+ or SFP28 transceivers.

    Important To prevent degraded performance, don't twist, fold, pinch, or step on the cables.
  4. Loosen the two captive screws on the appliance front panel.

    SGF6112 rack retaining screws
  5. Slide the SGF6112 forward out of the rack until the mounting rails are fully extended and you hear the latches on both sides click.

    The appliance top cover is accessible.

  6. Optional: If you are fully removing the appliance from the cabinet or rack, follow the instructions for the rail kit to remove the appliance from the rails.

After replacing the part, return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the Part Return & Replacements page for further information.

Related information

Remove SGF6112 cover