A newer release of this product is available.
monitor.completed events
monitor.completed EMS events occur when wafliron in the optional commit mode has finished on the aggregate but changes have not been committed or rejected.
monitor.completed.iron
- Severity
-
ERROR
- Description
-
This message occurs when wafliron in the optional commit mode has finished on the aggregate but changes have not been committed or rejected. Either commit or reject the changes.
- Corrective Action
-
Run the "aggr waflrion commit VOL" command to commit the changes or the "aggr wafliron reject VOL" command to reject the changes.
- Syslog Message
-
Wafliron in the optional commit mode has completed on aggregate '%s' but the changes have not been committed or rejected. Either commit or reject the changes.
- Parameters
-
volname (STRING): Volume name