Requirements to replace the controller - AFF C80
Before replacing the controller in your AFF C80 system, ensure you meet the necessary requirements for a successful replacement. This includes verifying all other components in the system are functioning properly, verifying that you have the correct replacement controller, and saving the controller's console output to a text log file.
Review the requirements for replacing the controller module.
|
|
NetApp strongly recommends that you enable console logging on the devices you are working with and take the following actions when performing this procedure:
|
-
All drive shelves must be working properly.
-
The healthy controller must be able to take over the controller being replaced (referred to in this procedure as the impaired controller).
-
Do not use this procedure for controller upgrades. Refer to Choose your controller hardware upgrade procedure for guidance.
-
If your system is in a MetroCluster configuration, review Choosing the correct recovery procedure to determine whether to use this procedure.
-
Replace the failed component with the field-replaceable unit (FRU) you received from NetApp.
-
Replace the controller module with a controller module of the same model type. You cannot upgrade your system by replacing the controller module.
-
You cannot change drives or drive shelves as part of this procedure.
-
The boot device is located on the System Management module installed in the back of the system. You do not need to move the boot device when replacing a controller module.
-
Understand the controller terminology used in this procedure:
-
The impaired controller is the controller being replaced.
-
The replacement controller is the new controller replacing the impaired controller.
-
The healthy controller is the surviving controller.
-
After you’ve reviewed the requirements to replace your AFF C80 controller, you need to shut down the impaired controller.