Replace the boot media - NS224 shelves
You can replace a failed boot media in an NS224 shelf. Replacing the boot media can be done nondisruptively, while the drive shelf is powered on, and I/O is in progress.
-
NS224 with NSM100 modules only: Your HA pair must already be running ONTAP 9.7 or later, which has the minimum supported version of NSM firmware.
You can enter the
storage shelf show -module
command at the console of either controller to verify the version of NSM firmware on your shelf.If your shelf is not running NSM firmware version 0111 or later, you cannot replace the boot media, you must replace the NSM.
-
NS224 with NSM100 modules only: You need a Phillips #1 screwdriver.
The screw used to secure the boot media to the board requires a Phillips #1 screwdriver; using a different type of screwdriver could strip the screw.
-
The shelf's partner NSM must be up and running, and be cabled correctly so that your shelf maintains connectivity when you remove the NSM with the failed FRU (target NSM).
-
All other components in the system must be functioning properly.
-
After the boot media is replaced, the boot image from the shelf's partner NSM is automatically copied to the replacement boot media.
This can take up to five minutes.
-
Allow at least 70 seconds between removal and installation of the NVMe shelf module (NSM).
This allows enough time for ONTAP to process the NSM removal event.
-
If needed, you can turn on the shelf's location (blue) LEDs to aid in physically locating the affected shelf:
storage shelf location-led modify -shelf-name shelf_name -led-status on
If you do not know the
shelf_name
of the affected shelf, run thestorage shelf show
command.A shelf has three location LEDs: one on the operator display panel and one on each NSM. Location LEDs remain illuminated for 30 minutes. You can turn them off by entering the same command, but using the
off
option. -
After replacing the boot media, you can return the failed part to NetApp as described in the RMA instructions shipped with the kit.
If you need the RMA number or additional help with the replacement procedure, contact technical support at NetApp Support, 888-463-8277 (North America), 00-800-44-638277 (Europe), or +800-800-80-800 (Asia/Pacific).
You can use the following animation or the written steps to replace the boot media.
-
Make sure that both NSMs in the shelf are running the same version of firmware: version 0200 or later.
-
Properly ground yourself.
-
Disconnect the cabling from the NSM that contains the FRU that you are replacing:
-
Disconnect the power cord from the power supply by opening the power cord retainer if it is an AC power supply, or unscrewing the two thumb screws if it is a DC power supply, and then unplug the power cord from the power supply.
Power supplies do not have a power switch.
-
Disconnect the storage cabling from the NSM ports.
Make a note of the NSM ports that each cable is connected to. You reconnect the cables to the same ports when you reinsert the NSM, later in this procedure.
-
-
Remove the NSM from the shelf:
-
Loop your index fingers through the finger holes of the latching mechanisms on either side of the NSM.
If you are removing the bottom NSM, and if the bottom rail is obstructing access to the latching mechanisms, place your index fingers through the finger holes from the inside (by crossing your arms). -
With your thumbs, press down and hold the orange tabs on top of the latching mechanisms.
The latching mechanisms raise, clearing the latching pins on the shelf.
-
Gently pull until the NSM is about one third of the way out of the shelf, grasp the NSM sides with both hands to support its weight, and then place it on a flat stable surface.
When you begin pulling, the latching mechanism arms extend from the NSM and lock in their fully extended position.
-
-
Loosen the NSM cover thumb screw and open the cover.
-
Physically locate the failed boot media.
The boot media is located along the shelf chassis wall opposite from the power supply.
-
Replace the boot media:
-
Using the Phillips #1 screwdriver, carefully remove the screw securing the bottom (notched) end of the boot media to the board.
-
Remove the boot media by rotating the notched end up slightly and then gently pulling it towards you until it releases from the socket.
You can hold the boot media by placing your thumb and forefinger on the side edges, at the notched end.
-
Unpack the boot media from the antistatic bag.
-
Insert the replacement boot media by pushing it gently into the socket until it is seated squarely and completely in the socket.
You can hold the boot media by placing your thumb and forefinger on the side edges, at the notched end. Make sure that the side with the heat sink is facing up.
When correctly seated, and when you let go of the boot media, the notched end of the boot media is angled up, away from the board, because it is not yet secured with the screw.
-
Gently hold down the notched end of the boot media as you insert and tighten the screw with the screwdriver to secure the boot media in place.
Tighten the screw just enough to hold the boot media securely in place, but do not overtighten.
-
-
Close the NSM cover, and then tighten the thumb screw.
-
Reinsert the NSM into the shelf:
-
Make sure that the latching mechanism arms are locked in the fully extended position.
-
Using both hands, gently slide the NSM into the shelf until the weight of the NSM is fully supported by the shelf.
-
Push the NSM into the shelf until it stops (about half an inch from the back of the shelf).
You can place your thumbs on the orange tabs on the front of each finger loop (of the latching mechanism arms) to push in the NSM.
-
Loop your index fingers through the finger holes of the latching mechanisms on either side of the NSM.
If you are inserting the bottom NSM, and if the bottom rail is obstructing access to the latching mechanisms, place your index fingers through the finger holes from the inside (by crossing your arms). -
With your thumbs, press down and hold the orange tabs on top of the latching mechanisms.
-
Gently push forward to get the latches over the stop.
-
Release your thumbs from the tops of the latching mechanisms, and then continue pushing until the latching mechanisms snap into place.
The NSM should be fully inserted into the shelf and flush with the edges of the shelf.
-
-
Reconnect the cabling to the NSM:
-
Reconnect the storage cabling to the same two NSM ports.
Cables are inserted with the connector pull-tab facing up. When a cable is inserted correctly, it clicks into place.
-
Reconnect the power cord to the power supply, and then secure the power cord with the power cord retainer if it is an AC power supply, or tighten the two thumb screws if it is a DC power supply.
When functioning correctly, a power supply's bicolored LED illuminates green.
Additionally, both NSM port LNK (green) LEDs illuminate. If a LNK LED does not illuminate, reseat the cable.
-
-
Verify that the attention (amber) LEDs on the NSM containing the failed boot media and the shelf operator display panel are no longer illuminated.
It can take between 5 to 10 minutes for the attention LEDs to turn off. This is the amount of time it takes the NSM to reboot and the boot media image copy to complete.
If the fault LEDs remain on, the boot media might not be seated correctly or there might be another issue and you should contact technical support for assistance.
-
Verify that the NSM is cabled correctly, by running Active IQ Config Advisor.
If any cabling errors are generated, follow the corrective actions provided.
You can use the following steps to replace the failed boot media.
-
Properly ground yourself.
-
Disconnect the cabling from the NSM that contains the FRU that you are replacing:
-
Disconnect the power cord from the power supply by opening the power cord retainer if it is an AC power supply, or unscrewing the two thumb screws if it is a DC power supply, and then unplug the power cord from the power supply.
Power supplies do not have a power switch.
-
Disconnect the storage cabling from the NSM ports.
Make a note of the NSM ports that each cable is connected to. You reconnect the cables to the same ports when you reinsert the NSM, later in this procedure.
-
-
Remove the NSM:
On both ends of the NSM, push the vertical locking tabs outward to release the handles.
-
Pull the handles towards you to unseat the NSM from the midplane.
As you pull, the handles extend out from the shelf. When you feel some resistance, keep pulling.
-
Slide the NSM out of the shelf and place it on a flat, stable surface.
Make sure that you support the bottom of the NSM as you slide it out of the shelf.
Rotate the handles upright (next to the tabs) to move them out of the way.
-
-
Open the NSM cover by turning the thumbscrew counterclockwise to loosen it, and then open the cover.
-
Physically locate the failed boot media.
-
Remove the boot media:
Boot media location
Press down on the blue tab to release the right end of the boot media.
Lift the right end of the boot media up at a slight angle to get a good grip along the sides of the boot media.
Gently pull the left end of the boot media out of its socket.
-
Install the replacement boot media:
-
Align the edges of the boot media with the socket housing, and then gently push it squarely into the socket.
-
Rotate the boot media down toward the locking button.
-
Push the locking button, rotate the boot media all the way down, and then release the locking button.
-
-
Close the NSM cover, and then tighten the thumb screw.
-
Insert the NSM into the shelf:
If you rotated the NSM handles upright (next to the tabs) to move them out of the way while you serviced the NSM, rotate them down to the horizontal position.
Align the rear of the NSM with the opening in the shelf, and then gently push the NSM using the handles until it is fully seated.
Rotate the handles to the upright position and lock in place with the tabs.
-
Reconnect the cabling to the NSM:
-
Reconnect the storage cabling to the same two NSM ports.
Cables are inserted with the connector pull-tab facing up. When a cable is inserted correctly, it clicks into place.
-
Reconnect the power cord to the power supply, and then secure the power cord with the power cord retainer if it is an AC power supply, or tighten the two thumb screws if it is a DC power supply.
When functioning correctly, a power supply's bicolored LED illuminates green.
Additionally, both NSM port LNK (green) LEDs illuminate. If a LNK LED does not illuminate, reseat the cable.
-
-
Verify that the attention (amber) LEDs on the NSM containing the failed boot media and the shelf operator display panel are no longer illuminated.
It can take between 5 to 10 minutes for the attention LEDs to turn off. This is the amount of time it takes the NSM to reboot and the boot media image copy to complete.
If the fault LEDs remain on, the boot media might not be seated correctly or there might be another issue and you should contact technical support for assistance.
-
Verify that the NSM is cabled correctly, by running Active IQ Config Advisor.
If any cabling errors are generated, follow the corrective actions provided.