Skip to main content
Install and maintain

Cable shelf to ASA systems - NS224 shelves

Contributors netapp-jsnyder netapp-lisa

You cable each NS224 shelf you are hot-adding so that each shelf has two connections to each controller in the HA pair.

Cable shelf to ASA A250 or ASA C250

When additional storage is needed, you can hot-add a maximum of one NS224 shelf to an AFF A250 or AFF C250 HA pair.

Before you begin
About this task

When viewed from the rear of the platform chassis, the RoCE-capable card port on the left is port "a" (e1a) and the port on the right is port "b" (e1b).

Steps
  1. Cable the shelf connections:

    1. Cable shelf NSM A port e0a to controller A slot 1 port a (e1a).

    2. Cable shelf NSM A port e0b to controller B slot 1 port b (e1b).

    3. Cable shelf NSM B port e0a to controller B slot 1 port a (e1a).

    4. Cable shelf NSM B port e0b to controller A slot 1 port b (e1b).
      The following illustration shows the shelf cabling when completed.

      Cabling for an AFF A250
  2. Verify that the hot-added shelf is cabled correctly using Active IQ Config Advisor.

    If any cabling errors are generated, follow the corrective actions provided.

What's next?

If you disabled automatic drive assignment as part of the preparation for this procedure, you need to manually assign drive ownership and then reenable automatic drive assignment, if needed. Go to Complete the hot-add.

Otherwise, you are done with the hot-add shelf procedure.

Cable shelf to ASA A400 or ASA C400

How you cable an NS224 shelf for a hot-add depends on whether you have an AFF A400 or AFF C400 HA pair.

Before you begin

Cable shelf to an AFF A400 HA pair

For an AFF A400 HA pair, you can hot-add up to two shelves and use onboard ports e0c/e0d and ports in slot 5 as needed.

Steps
  1. If you are hot-adding one shelf using one set of RoCE-capable ports (onboard RoCE-capable ports) on each controller, and this is the only NS224 shelf in your HA pair, complete the following substeps.

    Otherwise, go to the next step.

    1. Cable shelf NSM A port e0a to controller A port e0c.

    2. Cable shelf NSM A port e0b to controller B port e0d.

    3. Cable shelf NSM B port e0a to controller B port e0c.

    4. Cable shelf NSM B port e0b to controller A port e0d.

      The following illustration shows cabling for one hot-added shelf using one set of RoCE-capable ports on each controller:

      Cabling for an AFF A400 with one NS224 shelf and one set of onboard ports
  2. If you are hot-adding one or two shelves using two sets of RoCE-capable ports (on board and PCIe card RoCE-capable ports) on each controller, complete the following substeps.

    Shelves Cabling

    Shelf 1

    1. Cable NSM A port e0a to controller A port e0c.

    2. Cable NSM A port e0b to controller B slot 5 port 2 (e5b).

    3. Cable NSM B port e0a to controller B port e0c.

    4. Cable NSM B port e0b to controller A slot 5 port 2 (e5b).

    5. If you are hot-adding a second shelf, complete the “Shelf 2” substeps; otherwise, go to step 3.

    Shelf 2

    1. Cable NSM A port e0a to controller A slot 5 port 1 (e5a).

    2. Cable NSM A port e0b to controller B port e0d.

    3. Cable NSM B port e0a to controller B slot 5 port 1 (e5a).

    4. Cable NSM B port e0b to controller A port e0d.

    5. Go to step 3.

    The following illustration shows cabling for two hot-added shelves:

    Cabling for an AFF A400 with two NS224 shelves and one set of onboard ports and one set of ports on PCIe cards
  3. Verify that the hot-added shelf is cabled correctly using Active IQ Config Advisor.

    If any cabling errors are generated, follow the corrective actions provided.

  4. If you disabled automatic drive assignment as part of the preparation for this procedure, you need to manually assign drive ownership and then re enable automatic drive assignment, if needed. See Complete the hot-add.

    Otherwise, you are done with this procedure.

Cable shelf to an AFF C400 HA pair

For an AFF C400 HA pair, you can hot-add up to two shelves and use ports in slot 4 and 5 as needed.

Steps
  1. If you are hot-adding one shelf using one set of RoCE-capable ports on each controller, and this is the only NS224 shelf in your HA pair, complete the following substeps.

    Otherwise, go to the next step.

    1. Cable shelf NSM A port e0a to controller A slot 4 port 1 (e4a).

    2. Cable shelf NSM A port e0b to controller B slot 4 port 2 (e4b).

    3. Cable shelf NSM B port e0a to controller B slot 4 port 1 (e4a).

    4. Cable shelf NSM B port e0b to controller A slot 4 port 2 (e4b).

      The following illustration shows cabling for one hot-added shelf using one set of RoCE-capable ports on each controller:

      Cabling for an AFF C400 with one NS224 shelf and one set of PCIe card ports
  2. If you are hot-adding one or two shelves using two sets of RoCE-capable ports on each controller, complete the following substeps.

    Shelves Cabling

    Shelf 1

    1. Cable NSM A port e0a to controller A slot 4 port 1 (e4a).

    2. Cable NSM A port e0b to controller B slot 5 port 2 (e5b).

    3. Cable NSM B port e0a to controller B port slot 4 port 1 (e4a).

    4. Cable NSM B port e0b to controller A slot 5 port 2 (e5b).

    5. If you are hot-adding a second shelf, complete the “Shelf 2” substeps; otherwise, go to step 3.

    Shelf 2

    1. Cable NSM A port e0a to controller A slot 5 port 1 (e5a).

    2. Cable NSM A port e0b to controller B slot 4 port 2 (e4b).

    3. Cable NSM B port e0a to controller B slot 5 port 1 (e5a).

    4. Cable NSM B port e0b to controller A slot 4 port 2 (e4b).

    5. Go to step 3.

    The following illustration shows cabling for two hot-added shelves:

    Cabling for an AFF C400 with two NS224 shelves and two sets of PCIe card ports
  3. Verify that the hot-added shelf is cabled correctly using Active IQ Config Advisor.

    If any cabling errors are generated, follow the corrective actions provided.

What's next?

If you disabled automatic drive assignment as part of the preparation for this procedure, you need to manually assign drive ownership and then reenable automatic drive assignment, if needed. Go to Complete the hot-add.

Otherwise, you are done with the hot-add shelf procedure.

Cable shelf to ASA A800 or ASA C800

How you cable an NS224 shelf in an AFF A800 or AFF C800 HA pair depends on the number of shelves you are hot-adding and the number of RoCE-capable port sets (one or two) you are using on the controllers.

Before you begin
Steps
  1. If you are hot-adding one shelf using one set of RoCE-capable ports (one RoCE-capable PCIe card) on each controller, and this is the only NS224 shelf in your HA pair, complete the following substeps.

    Otherwise, go to the next step.

    Note This step assumes you installed the RoCE-capable PCIe card in slot 5.
    1. Cable shelf NSM A port e0a to controller A slot 5 port a (e5a).

    2. Cable shelf NSM A port e0b to controller B slot 5 port b (e5b).

    3. Cable shelf NSM B port e0a to controller B slot 5 port a (e5a).

    4. Cable shelf NSM B port e0b to controller A slot 5 port b (e5b).

      The following illustration shows cabling for one hot-added shelf using one RoCE-capable PCIe card on each controller:

      Cabling for an AFF A800 or AFF C800 with one NS224 shelf and one PCIe card
  2. If you are hot-adding one or two shelves using two sets of RoCE-capable ports (two RoCE-capable PCIe cards) on each controller, complete the applicable substeps.

    Note This step assumes you installed the RoCE-capable PCIe cards in slot 5 and slot 3.
    Shelves Cabling

    Shelf 1

    Note These substeps assume you are beginning the cabling by cabling shelf port e0a to the RoCE-capable PCIe card in slot 5, instead of slot 3.
    1. Cable NSM A port e0a to controller A slot 5 port a (e5a).

    2. Cable NSM A port e0b to controller B slot 3 port b (e3b).

    3. Cable NSM B port e0a to controller B slot 5 port a (e5a).

    4. Cable NSM B port e0b to controller A slot 3 port b (e3b).

    5. If you are hot-adding a second shelf, complete the “Shelf 2” substeps; otherwise, go to step 3.

    Shelf 2

    Note These substeps assume you are beginning the cabling by cabling shelf port e0a to the RoCE-capable PCIe card in slot 3, instead of slot 5 (which correlates with the cabling substeps for shelf 1).
    1. Cable NSM A port e0a to controller A slot 3 port a (e3a).

    2. Cable NSM A port e0b to controller B slot 5 port b (e5b).

    3. Cable NSM B port e0a to controller B slot 3 port a (e3a).

    4. Cable NSM B port e0b to controller A slot 5 port b (e5b).

    5. Go to step 3.

    The following illustration shows cabling for two hot-added shelves:

    drw ns224 a800 c800 2shelves IEOPS 966
  3. Verify that the hot-added shelf is cabled correctly using Active IQ Config Advisor.

    If any cabling errors are generated, follow the corrective actions provided.

What's next?

If you disabled automatic drive assignment as part of the preparation for this procedure, you need to manually assign drive ownership and then reenable automatic drive assignment, if needed. Go to Complete the hot-add.

Otherwise, you are done with the hot-add shelf procedure.

Cable shelf to ASA A900

When additional storage is needed, you can hot-add up to three additional NS224 drive shelves (for a total of four shelves) to an AFF A900 HA pair.

Before you begin
About this task
  • This procedure assumes that your HA pair has at least one existing NS224 shelf and that you are hot-adding up to three additional shelves.

  • If your HA pair has only one existing NS224 shelf, this procedure assumes that the shelf is cabled across two RoCE-capable 100GbE I/O modules on each controller.

Steps
  1. If the NS224 shelf you are hot-adding will be the second NS224 shelf in the HA pair, complete the following substeps.

    Otherwise, go to the next step.

    1. Cable shelf NSM A port e0a to controller A slot 10 port a (e10a).

    2. Cable shelf NSM A port e0b to controller B slot 2 port b (e2b).

    3. Cable shelf NSM B port e0a to controller B slot 10 port a (e10a).

    4. Cable shelf NSM B port e0b to controller A slot 2 port b (e2b).

      The following illustration shows the second shelf cabling (and the first shelf).

      Cabling for an AFF A900 with two NS224 shelves and two IO modules
  2. If the NS224 shelf you are hot-adding will be the third NS224 shelf in the HA pair, complete the following substeps.

    Otherwise, go to the next step.

    1. Cable shelf NSM A port e0a to controller A slot 1 port a (e1a).

    2. Cable shelf NSM A port e0b to controller B slot 11 port b (e11b).

    3. Cable shelf NSM B port e0a to controller B slot 1 port a (e1a).

    4. Cable shelf NSM B port e0b to controller A slot 11 port b (e11b).

      The following illustration shows the third shelf cabling.

      Cabling for an AFF A900 with three NS224 shelves and four IO modules
  3. If the NS224 shelf you are hot-adding will be the fourth NS224 shelf in the HA pair, complete the following substeps.

    Otherwise, go to the next step.

    1. Cable shelf NSM A port e0a to controller A slot 11 port a (e11a).

    2. Cable shelf NSM A port e0b to controller B slot 1 port b (e1b).

    3. Cable shelf NSM B port e0a to controller B slot 11 port a (e11a).

    4. Cable shelf NSM B port e0b to controller A slot 1 port b (e1b).

      The following illustration shows the fourth shelf cabling.

      Cabling for an AFF A900 with four NS224 shelves and four IO modules
  4. Verify that the hot-added shelf is cabled correctly using Active IQ Config Advisor.

    If any cabling errors are generated, follow the corrective actions provided.

What's next?

If you disabled automatic drive assignment as part of the preparation for this procedure, you need to manually assign drive ownership and then reenable automatic drive assignment, if needed. Go to Complete the hot-add.

Otherwise, you are done with the hot-add shelf procedure.