Skip to main content
Install and maintain

Maintain AFF A800 hardware

Contributors dougthomp netapp-jsnyder

Maintain the hardware of your AFF A800 storage system to ensure long-term reliability and optimal performance. Perform regular maintenance tasks such as replacing faulty components, as this helps prevent downtime and data loss.

The maintenance procedures assume that the AFF A800 storage system has already been deployed as a storage node in the ONTAP environment.

System components

For the AFF A800 storage system, you can perform maintenance procedures on the following components.

The boot media stores a primary and secondary set of ONTAP image files that the storage system uses to boot. During automated recovery, the system retrieves the boot image from the partner node and automatically runs the appropriate boot menu option to install the image on your replacement boot media. The automated boot media recovery process is supported only in ONTAP 9.17.1 and later. If your storage system is running an earlier version of ONTAP, use the manual boot recovery procedure.

The boot media stores a primary and secondary set of ONTAP image files that the storage system uses to boot. During manual recovery, you boot the storage system from a USB drive and manually restore the file system image and configuration. If your storage system is running ONTAP 9.17.1 and later, use the automated boot recovery procedure.

The chassis is the physical enclosure housing all the controller components such as the controller/CPU unit, power supply, and I/O.

A controller consists of a board, firmware, and software. It controls the drives and implements the ONTAP functions.

You must replace a DIMM (dual in-line memory module) when a memory mismatch is present, or you have a failed DIMM.

A drive is a device that provides the physical storage media for data.

Fan

The fan cools the controller.

The NVDIMM (non-volatile dual in-line memory module) manages the data transfer from the volatile memory to the non-volatile storage, and maintains data integrity in the event of a power loss or system shutdown.

A NVDIMM battery is responsible for maintaining power to the NVDIMM module.

A PCIe (peripheral component interconnect express) card is an expansion card that plugs into the PCIe slot on the motherboard or into risers plugged into the motherboard.

A power supply provides a redundant power source in a controller shelf.

A real time clock battery preserves system date and time information if the power is off.