Autoconfigure storage array hot spares
The autoConfigure storageArray hotSpares
command automatically defines and configures the hot spares in a storage array. You can run this command at any time. This command provides the best hot spare coverage for a storage array.
Supported Arrays
This command applies to any individual storage array, including the E4000, E2700, E5600, E2800, E5700, EF600 and EF300 arrays, as long as all SMcli packages are installed.
Roles
To execute this command on an E4000, E2800, E5700, EF600, or EF300 storage array, you must have the Storage Admin role.
Syntax
autoConfigure storageArray hotSpares
Parameters
None.
Notes
When you run the autoconfigure storageArray hotSpares
command, the controller firmware determines the number of hot spares to create based on the total number and type of drives in the storage array. For SAS drives, the controller firmware creates one hot spare for the storage array and one additional hot spare for every 60 drives in the storage array.
Minimum firmware level
6.10