Save drive channel fault isolation diagnostic status
The save driveChannel faultDiagnostics file
command saves the drive channel fault isolation diagnostic data that is returned from the start driveChannel faultDiagnostics
command.
Supported Arrays
This command applies to any individual storage array, including the E2700, E5600, E2800, E5700, EF600 and EF300 arrays, as long as all SMcli packages are installed.
Roles
To execute this command on an E2800, E5700, EF600, or EF300 storage array, you must have the Storage Admin role.
Context
With firmware version 8.10, the |
You can save the diagnostic data to a file as standard text or as XML.
Syntax
save driveChannel faultDiagnostics file="filename"
Parameter
Parameter | Description |
---|---|
|
The file path and the file name to which you want to save the results of the fault isolation diagnostics test on the drive channel. Enclose the file name in double quotation marks (" "). For example:
This command does not automatically append a file extension to the saved file. You must specify a file extension when entering the file name. |
Notes
A file extension is not automatically appended to the saved file. You must specify the applicable format file extension for the file. If you specify a file extension of .txt
, the output will be in a text file format. If you specify a file extension of .xml
, the output will be in an XML file format.
Minimum firmware level
7.15 introduces this new capability for legacy controller trays.