Configure switches for FCoE
You must configure your switches for FCoE before your FC service can run over the existing Ethernet infrastructure.
-
Your SAN configuration must be supported.
For more information about supported configurations, see the NetApp Interoperability Matrix Tool.
-
A Unified Target Adapter (UTA) must be installed on your storage system.
If you are using a UTA2, it must be set to
cna
mode. -
A converged network adapter (CNA) must be installed on your host.
-
Use your switch documentation to configure your switches for FCoE.
-
Verify that the DCB settings for each node in the cluster have been correctly configured.
run -node node1 -command dcb show
DCB settings are configured on the switch. Consult your switch documentation if the settings are incorrect.
-
Verify that the FCoE login is working when the FC target port online status is
true
.fcp adapter show -fields node,adapter,status,state,speed,fabric-established,physical-protocol
If the FC target port online status is
false
, consult your switch documentation.