Skip to main content

Commands for managing FC adapters

Contributors netapp-aherbin

You can use FC commands to manage FC target adapters, FC initiator adapters, and onboard FC adapters for your storage controller. The same commands are used to manage FC adapters for the FC protocol and the FC-NVMe protocol.

FC initiator adapter commands work only at the node level. You must use the run -node node_name command before you can use the FC initiator adapter commands.

Commands for managing FC target adapters

If you want to…​ Use this command…​

Display FC adapter information on a node

network fcp adapter show

Modify FC target adapter parameters

network fcp adapter modify

Display FC protocol traffic information

run -node node_name sysstat -f

Display how long the FC protocol has been running

run -node node_name uptime

Display adapter configuration and status

run -node node_name sysconfig -v adapter

Verify which expansion cards are installed and whether there are any configuration errors

run -node node_name sysconfig -ac

View a man page for a command

man command_name

Commands for managing FC initiator adapters

If you want to…​ Use this command…​

Display information for all initiators and their adapters in a node

run -node node_name storage show adapter

Display adapter configuration and status

run -node node_name sysconfig -v adapter

Verify which expansion cards are installed and whether there are any configuration errors

run -node node_name sysconfig -ac

Commands for managing onboard FC adapters

If you want to…​ Use this command…​

Display the status of the onboard FC ports

run -node node_name system hardware unified-connect show