A newer release of this product is available.
storage firmware shelf show
Contributors
Suggest changes
- PDF of this doc site
Collection of separate PDF docs
Creating your file...
This may take a few minutes. Thanks for your patience.
Your file is ready
Display the list of shelf firmware files on the given node
Availability: This command is available to cluster administrators at the admin privilege level.
Description
The storage firmware shelf show
command displays the shelf firmware files present on each node.
Parameters
- {
[-fields <fieldname>,…]
-
If you specify the
-fields <fieldname>, …
parameter, the command output also includes the specified field or fields. You can use '-fields ?' to display the fields to specify. - |
[-instance ]
} -
If you specify the
-instance
parameter, the command displays detailed information about all fields. [-node {<nodename>|local}]
- Node-
Selects the files that match the specified node name.
[-filename <text>]
- Storage Firmware File-
Selects the files that match the specified filename.
Examples
The following example displays the shelf firmware files on each node:
cluster1::> storage firmware shelf show Node: Node1 Shelf Firmware Files ---------------------------------------- AT-FCX.3800.SFW AT-FCX.3800.SFW.FVF ESH4.1400.SFW ESH4.1400.SFW.FVF Node: Node2 Shelf Firmware Files ---------------------------------------- AT-FCX.3800.SFW AT-FCX.3800.SFW.FVF ESH4.1400.SFW ESH4.1400.SFW.FVF 8 entries were displayed.