FC Target port configuration recommendations
-
PDF of this doc site
- Cluster administration
-
Volume administration
- Logical storage management with the CLI
-
NAS storage management
- Configure NFS with the CLI
- Manage NFS with the CLI
-
Manage SMB with the CLI
- Manage file access using SMB
- Security and data encryption
- Data protection and disaster recovery
Collection of separate PDF docs
Creating your file...
For best performance and highest availability, you should use the recommended FC target port configuration.
The following table shows the preferred port usage order for onboard FC and FC-NVMe target ports. For expansion adapters, the FC ports should be spread so that they do not use the same ASIC for connectivity. The preferred slot order is listed in NetApp Hardware Universe for the version of ONTAP software used by your controller.
FC-NVMe is supported on the following models:
-
AFF A300
The AFF A300 onboard ports do not support FC-NVMe.
-
AFF A700
-
AFF A700s
-
AFF A800
The FAS2520 systems do not have onboard FC ports and do not support add-on adapters. |
Controller | Port pairs with shared ASIC | Number of target ports: Preferred ports |
---|---|---|
FAS9000, AFF A700, AFF A700s and AFF A800 |
None |
All data ports are on expansion adapters. See NetApp Hardware Universe for more information. |
8080, 8060 and 8040 |
0e+0f 0g+0h |
1: 0e 2: 0e, 0g 3: 0e, 0g, 0h 4: 0e, 0g, 0f, 0h |
FAS8200 and AFF A300 |
0g+0h |
1: 0g 2: 0g, 0h |
8020 |
0c+0d |
1: 0c 2: 0c, 0d |
62xx |
0a+0b 0c+0d |
1: 0a 2: 0a, 0c 3: 0a, 0c, 0b 4: 0a, 0c, 0b, 0d |
32xx |
0c+0d |
1: 0c 2: 0c, 0d |
FAS2554, FAS2552, FAS2600 series,FAS2720,FAS2750, AFF A200 and AFF A220 |
0c+0d 0e+0f |