mgmt.smbc events
mgmt.smbc.config.not.repl
- Severity
 - 
NOTICE
 - Description
 - 
This message occurs when the system fails to replicate the configuration of Report Target Group Port(RTPG) and Inter-Cluster(IC) LIF information.
 - Corrective Action
 - 
(None).
 - Syslog Message
 - 
Failure in configuration replication of RTPG, IC LIF information with relationship UUID "%s".
 - Parameters
 - 
srcpath (STRING): Path name of the source group of the SnapMirror Business Continuity relationship.
dstpath (STRING): Path name of the destination group of the SnapMirror Business Continuity relationship.
relationship_id (STRING): Relationship UUID. 
mgmt.smbc.proxy.create.fail
- Severity
 - 
ERROR
 - Description
 - 
This message occurs when there is a failure to create proxy I/O path channel between the SMBC peer clusters.
 - Corrective Action
 - 
Check the network connection between the source and destination volumes by using the "net interface show -role intercluster -status-admin up" command.
 - Syslog Message
 - 
Failure in proxy initiator %s and target %s creation.
 - Parameters
 - 
proxy_initiator (STRING): Path name of the proxy initiator.
proxy_target (STRING): Path name of the proxy target.
relationship_id (STRING): Relationship UUID.
error_msg (STRING): Description of the failure.