Skip to main content
A newer release of this product is available.

dbs.disconn events

Contributors
Suggest changes

dbs.disconn.cluster.pair

Severity

ERROR

Description

This message occurs when the distributed block store detects that a cluster pair is disconnected or configured incorrectly. The distibuted block store is responsible for managing the data that backs the flexible volumes.

Corrective Action

Check network connectivity between clusters. One of the clusters in the pair might have become misconfigured or disconnected. Remove the local pairing and retry pairing the clusters.

Syslog Message

The distributed block store detects that the cluster pair is disconnected or configured incorrectly. The cluster fault type is %s and fault id is %u.

Parameters

cfType (STRING): Distibuted block store cluster fault type of the associated object.
cfID (INT): Distibuted block store cluster fault ID number associated with the fault.
cfStatus (INT): Current status of the cluster fault. 1 = New (just reported), 2 = Existing (updated), 3 = Resolved (closed).
cfDetails (STRING): Description of the cluster fault, including context details.
cfExtSrc (STRING): Distibuted block store cluster fault external source label created by the "CreateClusterFault" API command and attached to the fault for testing purposes.

dbs.disconn.remote.node

Severity

ERROR

Description

This message occurs when the Distributed Block Store (DBS) detects that a remote node is not connected to cluster network. The DBS is responsible for managing the data that backs the FlexVols®.

Corrective Action

Ping the remote nodes using jumbo frames to test network connectivity.

Syslog Message

The Distributed Block Store has detected that a remote node is not connected to cluster network. The cluster fault type is %s and fault id is %u.

Parameters

cfType (STRING): DBS cluster fault type of the associated object.
cfID (INT): DBS cluster fault ID number associated with the fault.
cfStatus (INT): Current status of the cluster fault. 1 = New (just reported), 2 = Existing (updated), 3 = Resolved (closed).
cfDetails (STRING): Description of the cluster fault, including context details.
cfExtSrc (STRING): DBS cluster fault externalSource label created by the CreateClusterFault API command and attached to the fault for testing purposes.