nvme.card events
Collection of separate PDF docs
Creating your file...
nvme.card.degraded
- Severity
-
ERROR
- Description
-
This message occurs when the NVMe caching module has gone into a degraded state due to a warning reported by the drive. Performance, integrity, or reliability may be compromised.
- Corrective Action
-
Replace the NVMe caching module.
- Syslog Message
-
NVMe caching module in slot %s with serial number %s, and model number %s is degraded with status 0x%llx.
- Parameters
-
slot_subslot (STRING): PCI slot of the NVMe device.
serial (STRING): Serial number of the controller.
model (STRING): Model number of the controller.
reason (LONGINTHEX): Internal reason why the card is degraded.
nvme.card.removed
- Severity
-
ERROR
- Description
-
This message occurs when an NVMe drive has been "hot-removed" from the system (while the system was powered on). The caching module is unavailable and system performance will be degraded.
- Corrective Action
-
Insert an NVMe caching module into the system.
- Syslog Message
-
NVMe caching module in slot %s with serial number %s, and model number %s was removed from the system.
- Parameters
-
slot_subslot (STRING): PCI slot of the NVMe device.
serial (STRING): Serial number of the controller.
model (STRING): Model number of the controller.