acp.commErrPersist
- Severity
-
ALERT
- Description
-
This message occurs when the Alternate Control Path (ACP) Administrator determines that a SAS shelf I/O module (IOM) configured for in-band ACP is experiencing persistent communication errors.
- Corrective Action
-
Examine the event log for I/O errors that might have a common source with this problem, such as faulty cabling. If other devices are not experiencing failures, then contact NetApp technical support to replace the IOM.
- Syslog Message
-
IOM %s has failed after reporting multiple in-band ACP errors. Shelf serial number: %s.
- Parameters
-
inband_id (STRING): Inband ID of the module.
shelf_sno (STRING): Storage shelf serial number of the shelf where the IOM is seated.